CAS 11096-82-5C12H4Cl6MW 360.9

AROCLOR 1260, 1X1ML, ISO, 1000UG/ML (CAS 11096-82-5) — formula C12H4Cl6, molecular weight 360.9; category organic chemicals.

Product Overview

CAS Number11096-82-5
Molecular FormulaC12H4Cl6
Molecular Weight360.9
Boiling Point725 to 788 °F at 760 mmHg (NTP, 1992)
LogPlog Kow = 6.8
ApplicationsUses: Formerly used in electrical transformers, hydraulic fluids, plasticizer in synthetic resins and dedusting agents. Although the production and sale was discontinued in late 1977, it is still present in many of the transformers and capacitors now in use., As of Jan 1979, Aroclors, including Aroclor 1260, are no longer used in the production of capacitors and transformers. Nevertheless, the life expectancy of transformers containing PCBs is > 30 yrs and the life expectancy of capacitors ranges from 10 to 20 yrs, depending on the electrical application ... In 1981, an estimated 131, 200 transformers containing PCBs were in service in the US, representing approx 1% of all operational transformers., Summary of former end uses for various Aroclors:, Table: Aroclor [Table#3667], PCBs were used as coolants and lubricants in transformers, capacitors, and other electrical devices (such as fluorescent lights and refridgerators) produced before 1977. PCBs may contaminate the air and water near hazardous waste sites. In addition, PCBs bioaccumulate in the environment and may be found in fish, meat, and dairy products. (L4), Methods of Manufacturing: PCBs, were, ... prepared industrially by the chlorination of biphenyl with anhydrous chlorine in the presence of a catalyst such as iron filings or ferric chloride. The products are complex mixtures of chlorobiphenyls, whose degree of chlorination depends principally on the time of contact (12-36 hr) of the biphenyl with anhydrous chlorine. The crude product is blown with air, and a small amount of lime is added to remove hydrogen chloride and ferric chloride. The resulting chlorinated mixtures are batch-distilled to remove color and traces of hydrogen chloride and ferric chloride., Polychlorinated biphenyls, The approximate distribution of chlorinated biphenyls in Aroclor 1260 is: <0.3% tri-, <0.3% tetra-, 9.2% penta-, 46.9% hexa-, 36.9% hepta-, 6.3% octa-, and 0.7% nonachlorobiphenyl., Impurities: Polychlorinated naphthalenes have also been identified in small quantities in, Aroclor 1260, ., PCDF Impurities in ppm: Cl3, 0.01, Cl4, 0.2-0.8, Cl5, 0.26-0.9, Cl6, 0.3-0.5, Cl7, 1.3. Toxic PCDF levels: 2, 3, 7, 8-TCDF, 0.013 ppm, 1, 2, 4, 8-, 8-PECDF, 0.048, 0.056, 9-, 0.5, 6, 8-HXCDF, 0.12, 8, 9-HXCDF, 0.19, 0.027., Concns of chlorinated dibenzofurans in commercial Aroclor mixtures: tetrachloro, 0.1-0.8 ug, g, pentachloro-, 0.3-3.6 ug, hexachloro-, 0.3-1.9 ug, Formulations, Preparations: Aroclor 1260 is a polychlorobiphenyl mixture containing 60% chlorine. It is composed of 12% penta-, 38% hexa-, 41% hepta-, 8% octa-, and 1% nona-chlorobiphenyls., Congener composition: Cl4, 1%, 12%, 38%, 41%, Cl8, 8%, Composition: pentachlorobiphenyls 12%, hexachlorobiphenyls 38%, heptachlorobiphenyls 41%, octachlorobiphenyls 8%, nonachlorobiphenyl 1%., Consumption Patterns: Not used commercially in USA, Domestic sales in millions of pounds of Monsanto's Aroclor 1260 in the United States from 1957 to 1970 are as follows: 7.6 (1957), 6.0 (1958), 6.6 (1959), 7.3 (1960), 6.5 (1961), 6.6 (1962), 7.6 (1963), 8.5 (1964), 5.8 (1965), 5.9 (1966), 6.4 (1967), 5.3 (1968), 4.4 (1969), and 4.9 (1970)., U.S. Production: (1982) Not produced commercially in USA, Production, discontinued in October 1977, U.S. Imports: (1978) 2.19 X10+8 g (Princpl Custms Dists) - PCBs, General Manufacturing Information: Total US sales in 1970 counted to 33.2 million kg and comprised ... 2.2 million kg Aroclor 1260 ..., Aroclor 1260 is the formulation used mostly in large capacitors and transformers. Federal Register, AUG 1979., The Aroclors are characterized by four digit numbers. The first two digits indicate that the mixture contains biphenyls (12), triphenyls (54) or both (25, 44), the last two digits give the weight percent of chlorine in the mixture (e.g., Aroclor 1242 contains biphenyls with approximately 42% chlorine)., ... The average molecule in Aroclor 1260 has 6 substituent chlorines, but varying proportions of species with greater and lesser halogen content are found in the mixture depending on the manufacturing process., For more General Manufacturing Information (Complete) data for Aroclor 1260 (6 total), please visit the HSDB record page.
CategoryOrganic Chemicals

Applications

Documented applications: Uses: Formerly used in electrical transformers, hydraulic fluids, plasticizer in synthetic resins and dedusting agents. Although the production and sale was discontinued in late 1977, it is still present in many of the transformers and capacitors now in use., As of Jan 1979, Aroclors, including Aroclor 1260, are no longer used in the production of capacitors and transformers. Nevertheless, the life expectancy of transformers containing PCBs is > 30 yrs and the life expectancy of capacitors ranges from 10 to 20 yrs, depending on the electrical application ... In 1981, an estimated 131, 200 transformers containing PCBs were in service in the US, representing approx 1% of all operational transformers., Summary of former end uses for various Aroclors:, Table: Aroclor [Table#3667], PCBs were used as coolants and lubricants in transformers, capacitors, and other electrical devices (such as fluorescent lights and refridgerators) produced before 1977. PCBs may contaminate the air and water near hazardous waste sites. In addition, PCBs bioaccumulate in the environment and may be found in fish, meat, and dairy products. (L4), Methods of Manufacturing: PCBs, were, ... prepared industrially by the chlorination of biphenyl with anhydrous chlorine in the presence of a catalyst such as iron filings or ferric chloride. The products are complex mixtures of chlorobiphenyls, whose degree of chlorination depends principally on the time of contact (12-36 hr) of the biphenyl with anhydrous chlorine. The crude product is blown with air, and a small amount of lime is added to remove hydrogen chloride and ferric chloride. The resulting chlorinated mixtures are batch-distilled to remove color and traces of hydrogen chloride and ferric chloride., Polychlorinated biphenyls, The approximate distribution of chlorinated biphenyls in Aroclor 1260 is: <0.3% tri-, <0.3% tetra-, 9.2% penta-, 46.9% hexa-, 36.9% hepta-, 6.3% octa-, and 0.7% nonachlorobiphenyl., Impurities: Polychlorinated naphthalenes have also been identified in small quantities in, Aroclor 1260, ., PCDF Impurities in ppm: Cl3, 0.01, Cl4, 0.2-0.8, Cl5, 0.26-0.9, Cl6, 0.3-0.5, Cl7, 1.3. Toxic PCDF levels: 2, 3, 7, 8-TCDF, 0.013 ppm, 1, 2, 4, 8-, 8-PECDF, 0.048, 0.056, 9-, 0.5, 6, 8-HXCDF, 0.12, 8, 9-HXCDF, 0.19, 0.027., Concns of chlorinated dibenzofurans in commercial Aroclor mixtures: tetrachloro, 0.1-0.8 ug, g, pentachloro-, 0.3-3.6 ug, hexachloro-, 0.3-1.9 ug, Formulations, Preparations: Aroclor 1260 is a polychlorobiphenyl mixture containing 60% chlorine. It is composed of 12% penta-, 38% hexa-, 41% hepta-, 8% octa-, and 1% nona-chlorobiphenyls., Congener composition: Cl4, 1%, 12%, 38%, 41%, Cl8, 8%, Composition: pentachlorobiphenyls 12%, hexachlorobiphenyls 38%, heptachlorobiphenyls 41%, octachlorobiphenyls 8%, nonachlorobiphenyl 1%., Consumption Patterns: Not used commercially in USA, Domestic sales in millions of pounds of Monsanto's Aroclor 1260 in the United States from 1957 to 1970 are as follows: 7.6 (1957), 6.0 (1958), 6.6 (1959), 7.3 (1960), 6.5 (1961), 6.6 (1962), 7.6 (1963), 8.5 (1964), 5.8 (1965), 5.9 (1966), 6.4 (1967), 5.3 (1968), 4.4 (1969), and 4.9 (1970)., U.S. Production: (1982) Not produced commercially in USA, Production, discontinued in October 1977, U.S. Imports: (1978) 2.19 X10+8 g (Princpl Custms Dists) - PCBs, General Manufacturing Information: Total US sales in 1970 counted to 33.2 million kg and comprised ... 2.2 million kg Aroclor 1260 ..., Aroclor 1260 is the formulation used mostly in large capacitors and transformers. Federal Register, AUG 1979., The Aroclors are characterized by four digit numbers. The first two digits indicate that the mixture contains biphenyls (12), triphenyls (54) or both (25, 44), the last two digits give the weight percent of chlorine in the mixture (e.g., Aroclor 1242 contains biphenyls with approximately 42% chlorine)., ... The average molecule in Aroclor 1260 has 6 substituent chlorines, but varying proportions of species with greater and lesser halogen content are found in the mixture depending on the manufacturing process., For more General Manufacturing Information (Complete) data for Aroclor 1260 (6 total), please visit the HSDB record page..

Technical Profile

What this product is

AROCLOR 1260, 1X1ML, ISO, 1000UG/ML is a carbon-based organic compound with CAS registry number 11096-82-5 and molecular formula C12H4Cl6 (molecular weight 360.9), belonging to the organic chemicals segment of chemical raw materials.

Identification

CAS number: 11096-82-5

Its molecular formula C12H4Cl6 comprises 12 C, 4 H, 6 Cl atoms.

Also known as: AROCLOR 1260, 1X1ML, ISO, 1000UG/ML · 亚老哥尔-1260

Category: organic chemicals

Frequently Asked Questions

What is the CAS number of AROCLOR 1260, 1X1ML, ISO, 1000UG/ML?

The CAS registry number of AROCLOR 1260, 1X1ML, ISO, 1000UG/ML is 11096-82-5.

What is the molecular formula and molecular weight of AROCLOR 1260, 1X1ML, ISO, 1000UG/ML?

Molecular formula C12H4Cl6, molecular weight 360.9.

What other names is AROCLOR 1260, 1X1ML, ISO, 1000UG/ML known by?

It is also registered under: AROCLOR 1260, 1X1ML, ISO, 1000UG/ML, 亚老哥尔-1260.

What are the documented applications of AROCLOR 1260, 1X1ML, ISO, 1000UG/ML?

Recorded applications: Uses: Formerly used in electrical transformers, hydraulic fluids, plasticizer in synthetic resins and dedusting agents. Although the production and sale was discontinued in late 1977, it is still present in many of the transformers and capacitors now in use., As of Jan 1979, Aroclors, including Aroclor 1260, are no longer used in the production of capacitors and transformers. Nevertheless, the life expectancy of transformers containing PCBs is > 30 yrs and the life expectancy of capacitors ranges from 10 to 20 yrs, depending on the electrical application ... In 1981, an estimated 131, 200 transformers containing PCBs were in service in the US, representing approx 1% of all operational transformers., Summary of former end uses for various Aroclors:, Table: Aroclor [Table#3667], PCBs were used as coolants and lubricants in transformers, capacitors, and other electrical devices (such as fluorescent lights and refridgerators) produced before 1977. PCBs may contaminate the air and water near hazardous waste sites. In addition, PCBs bioaccumulate in the environment and may be found in fish, meat, and dairy products. (L4), Methods of Manufacturing: PCBs, were, ... prepared industrially by the chlorination of biphenyl with anhydrous chlorine in the presence of a catalyst such as iron filings or ferric chloride. The products are complex mixtures of chlorobiphenyls, whose degree of chlorination depends principally on the time of contact (12-36 hr) of the biphenyl with anhydrous chlorine. The crude product is blown with air, and a small amount of lime is added to remove hydrogen chloride and ferric chloride. The resulting chlorinated mixtures are batch-distilled to remove color and traces of hydrogen chloride and ferric chloride., Polychlorinated biphenyls, The approximate distribution of chlorinated biphenyls in Aroclor 1260 is: <0.3% tri-, <0.3% tetra-, 9.2% penta-, 46.9% hexa-, 36.9% hepta-, 6.3% octa-, and 0.7% nonachlorobiphenyl., Impurities: Polychlorinated naphthalenes have also been identified in small quantities in, Aroclor 1260, ., PCDF Impurities in ppm: Cl3, 0.01, Cl4, 0.2-0.8, Cl5, 0.26-0.9, Cl6, 0.3-0.5, Cl7, 1.3. Toxic PCDF levels: 2, 3, 7, 8-TCDF, 0.013 ppm, 1, 2, 4, 8-, 8-PECDF, 0.048, 0.056, 9-, 0.5, 6, 8-HXCDF, 0.12, 8, 9-HXCDF, 0.19, 0.027., Concns of chlorinated dibenzofurans in commercial Aroclor mixtures: tetrachloro, 0.1-0.8 ug, g, pentachloro-, 0.3-3.6 ug, hexachloro-, 0.3-1.9 ug, Formulations, Preparations: Aroclor 1260 is a polychlorobiphenyl mixture containing 60% chlorine. It is composed of 12% penta-, 38% hexa-, 41% hepta-, 8% octa-, and 1% nona-chlorobiphenyls., Congener composition: Cl4, 1%, 12%, 38%, 41%, Cl8, 8%, Composition: pentachlorobiphenyls 12%, hexachlorobiphenyls 38%, heptachlorobiphenyls 41%, octachlorobiphenyls 8%, nonachlorobiphenyl 1%., Consumption Patterns: Not used commercially in USA, Domestic sales in millions of pounds of Monsanto's Aroclor 1260 in the United States from 1957 to 1970 are as follows: 7.6 (1957), 6.0 (1958), 6.6 (1959), 7.3 (1960), 6.5 (1961), 6.6 (1962), 7.6 (1963), 8.5 (1964), 5.8 (1965), 5.9 (1966), 6.4 (1967), 5.3 (1968), 4.4 (1969), and 4.9 (1970)., U.S. Production: (1982) Not produced commercially in USA, Production, discontinued in October 1977, U.S. Imports: (1978) 2.19 X10+8 g (Princpl Custms Dists) - PCBs, General Manufacturing Information: Total US sales in 1970 counted to 33.2 million kg and comprised ... 2.2 million kg Aroclor 1260 ..., Aroclor 1260 is the formulation used mostly in large capacitors and transformers. Federal Register, AUG 1979., The Aroclors are characterized by four digit numbers. The first two digits indicate that the mixture contains biphenyls (12), triphenyls (54) or both (25, 44), the last two digits give the weight percent of chlorine in the mixture (e.g., Aroclor 1242 contains biphenyls with approximately 42% chlorine)., ... The average molecule in Aroclor 1260 has 6 substituent chlorines, but varying proportions of species with greater and lesser halogen content are found in the mixture depending on the manufacturing process., For more General Manufacturing Information (Complete) data for Aroclor 1260 (6 total), please visit the HSDB record page..

Which category does AROCLOR 1260, 1X1ML, ISO, 1000UG/ML belong to?

Category: Organic Chemicals.

PubChem Public Data

Independent reference data for AROCLOR 1260, 1X1ML, ISO, 1000UG/ML (CAS 11096-82-5), compiled from public chemistry databases.

Registry identifiers across databases

CAS 号11096-82-5
PubChem CID38018
分子式C12H4Cl6
IUPAC 名称1,2,3-trichloro-4-(2,3,4-trichlorophenyl)benzene
UNII(FDA)PJ11O9J71Y

Computed descriptors

Molecular Weight360.9
XLogP37.3
Hydrogen Bond Donor Count0
Hydrogen Bond Acceptor Count0
Rotatable Bond Count1
Exact Mass359.841466
Monoisotopic Mass357.844416
Topological Polar Surface Area0
Heavy Atom Count18

Physicochemical values on record

Boiling Point725 to 788 °F at 760 mmHg (NTP, 1992)
Flash Point286 °F (NTP, 1992)
SolubilityIn water, 0.080 mg/L at 24 °C
Density1.555 at 90 °C/4deg C; 1.566 at 15.5 °C/4 °C
Density1.56 @ 90°C
Vapor Pressure4.05X10-5 mm Hg at 25 °C
LogPlog Kow = 6.8
LogP6.62

Synonyms and trade names

2,2',3,3',4,4'-HEXACHLOROBIPHENYL; 38380-07-3; PCB 128; 2,3,4,2',3',4'-Hexachlorobiphenyl; PJ11O9J71Y; DTXSID50858932; RefChem:53431; DTXCID40101; 690-182-3; AROCLOR 1260; 11096-82-5; 2,2',3,3',4,4'-Hexachloro-1,1'-biphenyl; 1,2,3-trichloro-4-(2,3,4-trichlorophenyl)benzene; PCB No. 128; 1,1'-Biphenyl, 2,2',3,3',4,4'-hexachloro-; Phenoclor DP6

Regulatory listings held on file

GHS 通报统计7.3% (3 / 41)

GHS hazard classification

GHS 通报统计7.3% (3 / 41)
已通报的危害声明H373 (92.7%), H400 (92.7%), H410 (92.7%), H302 (20%)

What the public record says

亚老哥尔-1260·CAS 11096-82-5·C12H4Cl6。 UNII PJ11O9J71Y。沸点:760 mmHg 时 725 至 788 °F(NTP,1992);闪点:286°F(NTP,1992);溶解度:水中,24 °C 时为 0.080 mg/L。

Source: PubChem / Wikidata; the batch COA governs where values differ.

Request a Quote

✉ info@591daili.com☎ +86-18553102138📞 WhatsAppEmail InquiryWhatsApp Inquiry

Supplier: Jinan Shenghe Chemical Co., Ltd.

中文页面: 亚老哥尔-1260

鲁ICP备19031700号-2